Skip to content

Controller Hardware FAQ ​

Q1: The system time or date frequently resets, and the recorded time is inaccurate ​

  1. The backup battery on the controller mainboard is depleted

Q2: The C2200-A01 controller needs to wait more than 15 seconds after shutdown before powering on ​

This controller has capacitors; you need to wait for the capacitors to fully discharge

Q3: A 2207 version C2200-A01 controller upgraded to the RTL1 program, the controller connection is lost ​

Network port 1 cannot be pinged; use network port 2 to replace the controller program from the backend

Q4: When running on a computer with a virtual machine, the PC side shows "connection lost" even with the corresponding IP set ​

  1. Check whether the virtual machine IP subnet on the computer's network connection page is consistent 2. Check whether the virtual machine is running normally

Q5: How to use the X02 integrated drive cabinet without a teach pendant? ​

The teach pendant emergency stop needs to be bypassed; refer to the X02 specification wiring diagram or contact technical personnel for consultation.

Q6: Short-circuiting the emergency stop without a teach pendant ​

For the T01 integrated drive cabinet, short pins 5 and 16 of the teach pendant port; for a normal split type, short pins 15 and 16 of the teach pendant port

Q7: How to modify the controller IP ​

Set the network port to the desired IP, set the teach pendant IP to the same subnet, set the connection IP to the modified network port IP; multiple network port subnets cannot be set the same

Q8: Recovering the IP of the integrated drive cabinet ​

Plug a network cable into the LAN port of the integrated cabinet with IP 192.168.2.13, modify the IP in the run.sh file under the g folder. If it cannot be pinged, you need to use the serial port to access the backend.

Q9: X02-arm mainboard: flashing an image causes the network port to fail to connect ​

Delete the test script in the controller, delete rcS, and rename rcS-bak to rcS

Q10: Multi-network-port controller: after modifying the IP, you forgot what it was changed to, causing the connection to be lost ​

Connect to another network port; after successful connection, the IP of the network port just modified can be viewed on the IP modification screen.

Q11: The system time or date frequently resets, and the recorded time is inaccurate ​

The backup battery on the controller mainboard is depleted; replace the backup battery.