1 FINSTCP Instruction Overview

The FINSTCP instruction is used to manage FINSTCP communication connections in run mode, enabling Fins TCP protocol communication between the controller and PLC.

FINSTCP instruction overview

> 1.1 Open FINSTCP Connection

Instruction Function: Open the FINSTCP communication connection in run mode

Parameter Description:

ParameterDescription
Process NumberBind FINSTCP parameter process number

Usage Scenarios:

  • Establish communication connection when the program starts
  • Reconnect after communication is disconnected

> 1.2 Disconnect FINSTCP Connection

Instruction Function: Disconnect the FINSTCP communication connection in run mode

Parameter Description:

ParameterDescription
Process NumberBind FINSTCP parameter process number

Usage Scenarios:

  • Close communication connection when the program ends
  • Disconnect current connection when switching to a different PLC

> 1.3 Get FINSTCP Connection Status

Instruction Function: Store the FINSTCP connection status in a BOOL/GBOOL variable

Usage Method:

  • Determine the FINSTCP connection status by reading the variable value
  • Status is obtained each time the instruction is executed
  • Typically placed below "Open FINSTCP Connection"

Usage Example:

plaintext
// Example code
GET_FINSTCP_STATUS GB010  // Store connection status in GB010
IF GB010 == 1 THEN
    // Connection successful, execute subsequent operations
    ...
ELSE
    // Connection failed, execute error handling
    ...
ENDIF

2 FINSTCP Parameter Configuration

> 2.1 Parameter Description

The FINSTCP parameter configuration interface contains the following parameters:

ParameterExample ValueDescription
Process Number1A total of 9 process numbers are available; this process number has no actual significance
ConnectionParameter/Connect buttonAfter FinsTCP setup is complete, the connect button must be opened; this connect button can also be opened and closed via Open FINSTCP Connection and Disconnect FINSTCP Connection instructions
Communication StatusConnected/DisconnectedThe communication status on the right side shows the connection status
ProtocolFins TCPCommunication protocol type
IP192.168.1.10PLC device IP address
Port9600PLC device port number
Write Address1000PLC write address (PLC start address)
Read Address2000PLC read address (PLC start address)
Write AddressGB001, GI001Controller write address (local start address); PLC reads data from the controller and writes it to PLC; this value can be modified on the teach pendant
Read AddressGB500, GI500Controller read address (local start address); controller reads data written by PLC and stores it in the controller's global Boolean and global integer variables; this value cannot be modified via the teach pendant, but can be written via CX-Programmer software

Important Notes:

The PLC write address and read address values must not be set to the same value. Additionally, the variables in the controller's write address and read address must not be the same variables.

> 2.2 Parameter Setting Example

Typical Configuration Example:

ParameterValueDescription
Process Number1Use process number 1
IP192.168.1.10PLC IP address
Port9600PLC port number
Write Address (PLC)1000PLC memory address 1000 in CX-Programmer software
Read Address (PLC)2000PLC memory address 2000 in CX-Programmer software
Write Address (Controller)GB001, GI001Controller global Boolean and integer variable start address
Read Address (Controller)GB500, GI500Controller global Boolean and integer variable start address

3 Fins TCP Usage Workflow

Fins TCP usage workflow

> 3.1 Fins TCP Function Overview

Function Description: The Fins TCP function enables data interaction between the controller and PLC

Supported Protocol: Fins TCP

Scope of Application: This function only applies to Omron PLCs

Usage Workflow:

Connect PLC, controller, and computer -> Set FINSTCP parameters -> Open CX-Programmer software for read/write operations

> 3.2 Hardware Connection

Step: Connect the PLC, controller, and computer using network cables

Software Preparation: CX-Programmer software must be installed on the computer

Connection Topology:

┌─────────────┐
│   Computer   │
│ (CX-Programmer)
└──────┬──────┘

       │ Network cable

┌──────┴──────┐
│  Controller  │
│ (iNexBot)   │
└──────┬──────┘

       │ Network cable

┌──────┴──────┐
│ Omron PLC   │
└─────────────┘

> 3.3 Parameter Settings

Setting Path: [Settings] -> [Modbus Settings] -> [FINSTCP Parameters]

Setting Steps:

  1. Enter the teach pendant [Settings] menu

  2. Select [Modbus Settings]

  3. Click [FINSTCP Parameters]

  4. Set the relevant parameters:

    • IP Address: Enter the PLC address 192.168.1.10
    • Port: Enter the PLC port 9600
    • Write Address: Enter the PLC memory address 1000 from CX-Programmer software
    • Read Address: Enter the PLC memory address 2000 from CX-Programmer software
    • Write Address (Controller): Enter GB001 and GI001
    • Read Address (Controller): Enter GB500 and GI500

FINSTCP Parameter Details:

ParameterDescription
ConnectionAfter FinsTCP setup is complete, the connect button must be opened; this connect button can also be opened and closed via Open FINSTCP Connection and Disconnect FINSTCP Connection instructions; the communication status on the right side shows the connection status
IPPLC device IP address
PortPLC device port number
Write Address (PLC)PLC memory address 1000 in CX-Programmer software
Read Address (PLC)PLC memory address 2000 in CX-Programmer software
Write Address (Controller)Starting from GB001, sub-units from CX-Programmer software are written sequentially; the first 16 Boolean variables are filled by obtaining the controller status (see appendix table). Starting from GI001, units from CX-Programmer software are written sequentially; the first 6 integer variables are the robot's current Cartesian coordinates, and the remaining values are the controller's own values (see appendix table). All values above are obtained by CX-Programmer software from the controller; refer to the appendix table for specific meanings
Read Address (Controller)Starting from GB500, variable values are written by CX-Programmer software; the first 16 variables are written to control the controller (see appendix table for specific functions). Starting from GI500, values are written by CX-Programmer software. All values above can only be written via CX-Programmer software

Important Note:

One unit = 16 sub-units. Sub-units are written to Boolean variables, and units are written to integer variables.

> 3.4 CX-Programmer Operations

Operation Steps:

  1. Open Software: Open CX-Programmer software

  2. Create New Project:

    • Click [File]
    • Select [New]
    • Click [OK] without modifying the popup content
  3. Open Memory Interface:

    • Double-click [Memory]
    • Open the memory interface
  4. Open Table Interface:

    • Double-click [D]
    • Open a table interface
  5. Monitor Data:

    • Click the [Monitor] button
    • Values will appear in the table interface
    • Enter 1000 as the start address
    • Click [Binary]
    • The values in the table are sub-unit values
  6. Connection Verification:

    • After the controller and PLC are connected
    • The value below 9 in the table will continuously toggle between 1 and 0
  7. View Unit Values:

    • Click [Signed Decimal]
    • The values in the table are unit values
  8. Write Operations:

    • When writing from CX-Programmer software
    • The [Read-only] button in the new interface must be turned off
    • Then values can be written from the software

4 Controller Address Mapping Details

This chapter provides detailed explanations of the values in the controller's write addresses and read addresses.

> 4.1 Global Boolean Variables in Controller Write Address

Variable Range: First 128 global Boolean variables

Data Source: The values of these 128 variables are obtained by the PLC reading the controller

4.1.1 First 16 Status Variables

The values of the first 16 variables are obtained based on the controller's status.

Variable NumberMeaningCondition for Value 1Condition for Value 0
1stReserved--
2ndRun Mode StatusController is in run modeController is not in run mode
3rdRemote Mode StatusController is in remote modeController is not in remote mode
4thServo Ready StatusController servo is readyController servo is not ready
5thReserved--
6thEmergency Stop StatusController emergency stop activatedController emergency stop not activated
7thReserved--
8thProgram Running StatusProgram is running in controllerProgram is not running in controller
9thProgram Paused StatusProgram is paused in controllerProgram is not paused in controller
10thCommunication HeartbeatController and PLC communication connectedController and PLC communication disconnected
11thCommunication Connection StatusController and PLC communication status connectedController and PLC communication status not connected
12thTeach Mode StatusController is in teach modeController is not in teach mode
13th-16thReserved--

Variable Description:

  • 2nd variable (Run Mode): Value is 1 when the controller is in run mode, otherwise 0
  • 3rd variable (Remote Mode): Value is 1 when the controller is in remote mode, otherwise 0
  • 4th variable (Servo Ready): Value is 1 when the controller servo is ready, otherwise 0
  • 6th variable (Emergency Stop): Value is 1 when the controller emergency stop is activated, otherwise 0
  • 8th variable (Program Running): Value is 1 when a program is running in the controller, otherwise 0
  • 9th variable (Program Paused): Value is 1 when a program is paused in the controller, otherwise 0
  • 10th variable (Communication Heartbeat): After the controller and PLC communication is connected, this value toggles continuously between 1 and 0. (When this value is toggling continuously, it indicates that the controller and PLC are connected successfully.)
  • 11th variable (Communication Connection): Value is 1 when the controller and PLC communication status is connected; this value does not change
  • 12th variable (Teach Mode): Value is 1 when the controller is in teach mode, otherwise 0

4.1.2 User Variables 16-128

Description: The values of variables 16 to 128 in the global Boolean variables are the controller's own global Boolean variable values, which are also the values read by the PLC

Modifiability: These variable values can be directly modified and filled in via the teach pendant

> 4.2 Global Integer Variables in Controller Write Address

4.2.1 First 6 Coordinate Variables

Description: The values of the first 6 global integer variables in the controller's write address represent the robot's coordinate position values

Coordinate Variables:

Variable NumberCoordinate Meaning
1stX-axis coordinate
2ndY-axis coordinate
3rdZ-axis coordinate
4thRx-axis coordinate
5thRy-axis coordinate
6thRz-axis coordinate

4.2.2 Global Integer Variables 6-40

Description: Variables 6 through 40 display the values of the controller's global integer variables

Modifiability: These variable values can be modified and filled in via the teach pendant

> 4.3 Global Boolean Variables in Controller Read Address

Variable Range: First 128 global Boolean variables in the read address

Data Source: Values written by the PLC

4.3.1 Control Signal Variables

Variable NumberFunction DescriptionActivation Effect
1stReserved-
2ndServo Ready ControlWhen PLC writes value 1, the controller servo is ready (if this value is not changed to 0, the controller will remain in servo ready state)
3rdReserved-
4thProgram Start ControlWhen PLC writes value 1, the controller main program starts running (controller must be in run mode)
5thProgram Pause ControlWhen PLC writes value 1, the controller main program pauses (controller must be in run mode)
6thReserved-
7thAlarm Clear ControlWhen PLC writes value 1, the controller's alarm bar is cleared, with the same effect as the clear error button
8th-128thUser-definedUser-defined functions

Variable Description:

  • 2nd variable (Servo Ready): When PLC writes value 1, the controller servo is ready (if this value is not changed to 0, the controller will remain in servo ready state)
  • 4th variable (Program Start): When PLC writes value 1, the controller main program starts running (controller must be in run mode)
  • 5th variable (Program Pause): When PLC writes value 1, the controller main program pauses (controller must be in run mode)
  • 7th variable (Alarm Clear): When PLC writes value 1, the controller's alarm bar is cleared, with the same effect as the clear error button

> 4.4 Global Integer Variables in Controller Read Address

Variable Range: First 81 integer variables bound to the read address

Data Source: Values written by the PLC

Modifiability: These values must be modified and filled in via the PLC


5 Important Notes

5.1 Address Configuration Notes

NoteDescription
Address UniquenessThe PLC write address and read address values must not be set to the same value
Variable UniquenessThe variables in the controller's write address and read address must not be the same variables
Address RangeEnsure the address range is within the valid range to avoid address conflicts

5.2 Communication Connection Notes

NoteDescription
Protocol SupportThis function only applies to Omron PLCs
Network ConnectionEnsure the PLC, controller, and computer are properly connected via network cables
IP Address ConfigurationEnsure the IP addresses are in the same network segment
Port ConfigurationEnsure the port number is correct; the default is 9600

5.3 CX-Programmer Operation Notes

NoteDescription
Read-only ModeThe read-only button must be turned off before write operations
Monitor ModeData changes can be viewed in real-time in monitor mode
Heartbeat DetectionAfter successful communication, the heartbeat variable will toggle continuously
Data FormatBinary displays sub-unit values; signed decimal displays unit values

5.4 Variable Operation Notes

NoteDescription
Status VariablesThe first 16 Boolean variables are system status, read-only
User VariablesBoolean variables 16-128 are read/write
Coordinate VariablesThe first 6 integer variables are robot coordinates
Global VariablesVariables that can be modified via the teach pendant

6 Typical Application Scenarios

6.1 PLC Controls Robot Start/Stop

Scenario Description: Control the start and pause of the robot's main program via PLC

Implementation Method:

  1. Configure FINSTCP parameters
  2. Write 1 to the 4th variable of the controller's read address via CX-Programmer software to start the robot's main program
  3. Write 1 to the 5th variable of the controller's read address via CX-Programmer software to pause the robot's main program

Control Flow:

PLC writes GB504 (4th variable) = 1 -> Robot main program starts running
PLC writes GB505 (5th variable) = 1 -> Robot main program pauses

6.2 Robot Status Monitoring

Scenario Description: PLC monitors robot running status in real-time

Implementation Method:

  1. Configure FINSTCP parameters
  2. Read the first 16 variables of the controller's write address via CX-Programmer software
  3. Parse the status information of each variable

Status Monitoring:

Robot StatusCorresponding VariableCondition for Value 1
Run ModeGB002Controller is in run mode
Remote ModeGB003Controller is in remote mode
Servo ReadyGB004Controller servo is ready
Emergency StopGB006Controller emergency stop activated
Program RunningGB008Program is running in controller
Program PausedGB009Program is paused in controller
Communication HeartbeatGB010Controller and PLC communication connected
Communication ConnectionGB011Controller and PLC communication status connected
Teach ModeGB012Controller is in teach mode

6.3 Coordinate Data Interaction

Scenario Description: PLC reads the robot's current coordinate position

Implementation Method:

  1. Configure FINSTCP parameters
  2. Read the first 6 integer variables (GI001-GI006) of the controller's write address via CX-Programmer software
  3. Parse the coordinate values

Coordinate Variables:

Variable NumberVariable NameCoordinate Meaning
1stGI001X-axis coordinate
2ndGI002Y-axis coordinate
3rdGI003Z-axis coordinate
4thGI004Rx-axis coordinate
5thGI005Ry-axis coordinate
6thGI006Rz-axis coordinate

7 Troubleshooting

7.1 Common Issues

Fault SymptomPossible CauseSolution
Cannot connect to PLCIP address configuration errorCheck if the IP address is in the same network segment
Cannot connect to PLCPort number configuration errorCheck if the port number is 9600
Cannot connect to PLCNetwork cable connection abnormalCheck if the network cable connection is normal
Communication status shows disconnectedConnect button not clickedClick the connect button or use the Open FINSTCP Connection instruction
Heartbeat variable not togglingCommunication not establishedCheck network connection and configuration parameters
Cannot write dataRead-only mode not turned offTurn off the read-only button in CX-Programmer software
Cannot start programController not in run modeSwitch the controller to run mode
Cannot pause programController not in run modeSwitch the controller to run mode

7.2 Connection Status Determination

Normal Connection Status:

  • Communication status shows "Connected"
  • 10th variable (GB010) value toggles continuously between 1 and 0
  • 11th variable (GB011) value is 1

Abnormal Connection Status:

  • Communication status shows "Disconnected"
  • 10th variable (GB010) value does not toggle
  • 11th variable (GB011) value is 0

7.3 Heartbeat Detection Description

Heartbeat Variable: 10th variable (GB010)

Normal State: After the controller and PLC communication is connected, this value toggles continuously between 1 and 0

Determination Standard: When this value is toggling continuously, it indicates that the controller and PLC are connected successfully